老化房室体结构及用料说明:1、墙体材料:库体采用双面彩钢保温库板(EPS板、聚氨酯板或岩棉板)拼装而成,板材厚度由老化房本身的需求和客户的要求双向进行选择,库板板材厚度有50mm、60mm、70mm、100mm等规格,彩钢板的厚度有0.326mm、0.5mm等规格,整个库体采用钢架结构,铝型材等固定支撑,库体内外采用铝型材或不锈钢板包边;(地面处理部分根据客户要求),接合处打密封玻璃胶,有效保证房间的密封性与美观性。(房体材料的燃烧性能符合《建筑材料燃烧性能分级》B2级的规定。

Aging room structure and material description: 1. Wall material: The warehouse body is assembled with double-sided color steel thermal insulation warehouse board (EPS board, polyurethane board or rock wool board). The thickness of the board is selected by the needs of the aging room itself and the requirements of customers in two directions. The thickness of the warehouse board is 50mm, 60mm, 70mm, 100mm, and the thickness of the color steel plate is 0.326mm, 0.5mm, etc. The whole warehouse body is mined. Fixed support with steel frame structure, aluminium profiles, etc. Aluminum profiles or stainless steel sheets are used inside and outside the storehouse to wrap the edges; (Ground treatment part according to customer requirements), sealing glass glue is used at the joint to effectively ensure the sealing and aesthetics of the room. (The combustion performance of building materials conforms to the requirements of Classification of Combustion Performance of Building Materials B2 level. 2、老化房门洞与视窗设计:根据实际要求;

2. Design of aging doors and windows: according to actual requirements;

3、风力恒温系统;

3. Wind thermostat system;

风力管道系统符合《通风与空调工程施工质量验收规范》GB50243-2002标准,通常采用循环系统、加热系统和超温排风系统组成。循环系统、超温排风系统、加热系统及配套的风道系统安装于老化房顶部,不占用其它空间,,循环系统采用循环风机和配套风管进行循环,可保证测试区内温度均匀,加热系统采用电热器加热,加热器放置于老化房顶上循环风道中,四周加防火隔热材料。采用PID温度模块控制,温度到达产品所需要温度后,根据室内温度波动自动调节加热器功率大小配合保温库板的保温性,使室内温度精确稳定在所设定温度数值可在指定的时间内内将室温加至设定温度,当温度升至设定值时加热器停止加热.加热器具有过热保护装置(EGO),如客户自身产品发热则采用过热排风系统,发热量小采用电动百叶自动负压排风,发热量大则采用低噪音风机排风,用变频器控制其转速。

Wind power pipeline system meets the GB50243-2002 standard of "Acceptance and Acceptance Standard for Construction Quality of Ventilation and Air Conditioning Engineering". It usually consists of circulating system, heating system and over-temperature exhaust system. Circulation system, over-temperature exhaust system, heating system and supporting duct system are installed on the top of aging roof without occupying other space. Circulation system uses circulating fan and supporting duct to circulate, which can ensure uniform temperature in the test area. Heating system uses electric heater to heat, heater is placed in the circulating duct on the aging roof, and fire-proof and heat-insulating materials are added around it. PID temperature module is used to control the temperature. After the temperature reaches the required temperature of the product, the power of the heater is automatically adjusted according to the fluctuation of the indoor temperature and the insulation of the insulation panels, so that the indoor temperature can be accurately stabilized. The indoor temperature can be increased to the set temperature within a specified time. When the temperature rises to the set value, the heater stops heating. The heater has an overheating protection device. (EGO), if the customer's own products are heated, they use superheated exhaust system, electric louver automatic negative pressure exhaust system with small calorific value, low noise fan exhaust system with large calorific value, and frequency converter to control its speed.

循环控温过程:

Cyclic temperature control process:

当开机时加热器开始加热温度到达设定值时加热器停止加热

The heater stops heating when the heater starts to heat and reaches the set temperature.

随着时间的推移产品区温度会逐渐上升当温度超过设定上限时

As time goes on, the temperature in the product area will gradually rise when the temperature exceeds the set upper limit.

排风系统开始动作将产品区过热气体排室外。变频器会控制室外排风机进行运转,当温度下降至设定值下限时风机停止排风,排风系统同时关闭。循环系统在老化产品的过程中始终保持循环状态,以保证温度均衡。整套系统动作具有性能稳定,控制精确、温度波动小,均衡度高、噪音小等特点。

The exhaust system starts to operate and the superheated gas in the product area is discharged outdoors. The frequency converter will control the outdoor exhaust fan to run. When the temperature drops to the lower limit of the set value, the fan will stop exhaust and the exhaust system will be closed at the same time. The circulating system always keeps the circulating state during the aging process to ensure the temperature balance. The whole system has the characteristics of stable performance, precise control, small temperature fluctuation, high equilibrium and low noise.

噪音处理:

Noise handling:

采用低分贝的高品质循环风机,风管采用3mm厚石棉包裹,既保温又降低噪音,根据声学原理,所有动态部位采用帆布、弹簧进行软接处理,力求把噪音降到最低标准。

A low-grade high-quality circulating fan with 3 mm thick asbestos wrapped air duct is used to keep heat and reduce noise. According to the acoustic principle, canvas and springs are used for soft joint treatment in all dynamic parts in order to reduce noise to the lowest standard.

老化房控制系统;

Aging room control system;

采用两级PID调节加热量,实现对测试区(产品区)温度的精确控制,同时温度控制器可以对测试区任意温度进行滚动实时显示,有独立负载的还可以对负载区的温度进行监控,防止负载区温度过高,方便客户准确掌握测试区温度情况。控制系统还设定了各种保护功能,有超温报警保护、风机故障报警保护、无风报警保护、室内烟气感应报警保护等,完善的保护功能确保了老化房能长期稳定无故障运行。(可选PLC来控制)

Two-stage PID is used to adjust the heating quantity to realize the precise control of the temperature in the test area (product area). At the same time, the temperature controller can display any temperature in the test area in real-time rolling. The temperature in the load area can also be monitored with independent load to prevent the temperature in the load area from being too high, so as to facilitate customers to accurately grasp the temperature situation in the test area. The control system also sets up various protection functions, such as overtemperature alarm protection, fan fault alarm protection, windless alarm protection, indoor smoke induction alarm protection, etc. The perfect protection function ensures the long-term stable and trouble-free operation of the aging room. (Optional PLC control)

产品测试架:(可选)

Product test stand: (optional)

产品测试架通常根据客户产品和要求进行设计制。如需负载,则做相对应的负载框架配套生产,一般测试架的设计要求结构稳固合理,操作方便,外形美观、满足功能等特点,最大限度的满足客户的要求。

Product test stand is usually designed according to customer's products and requirements. If the load is needed, the corresponding supporting production of the load frame is made. The design of the general test frame requires that the structure is stable and reasonable, the operation is convenient, the appearance is beautiful, and the function is satisfied, so as to meet the customer's requirements to the greatest extent.

控制系统设计以及安全保护措施:

Control system design and safety measures:

电控设计参照《低压配电设计规范》GB50054-95,

The design of electronic control refers to the Code for Design of Low Voltage Distribution GB50054-95.

《供配电设计规范》GB5002S2-95,

Code for Design of Power Supply and Distribution GB5002S2-95,

《电气装置安装工程接地装置施工及验收规范》GB50169-92,使电控设计标准化。

"Code for Construction and Acceptance of Grounding Devices in Electrical Installation Works" GB50169-92 standardizes the design of electronic control.